DVR Series Voltage Restorer, Deep Voltage Sag Corrector


DVR Series Voltage Restorer, Deep Voltage Sag Corrector

Typical Specifications, Technical Data & Common Options

Application
Power Rating/Size (kVA) 10, 20, 30, 50 75, 100, 150, 200, 300, 500, 750, 1,000 typical – up to 1,500 kVA available
Phase - Frequency (Hz) Three phase only- 50 or 60 Hz
Voltages 120, 208, 220, 240, 380, 400, 440, 480, 600 are typical.  Custom voltages available For voltage step up or step down contact factory
Connections 3 wire input and output
Cable Entry Side, back, top bottom, depending on enclosure type  – contact factory for details
Sag Correction/Regulation
Sag Correction 1 or 2 phase sags - to 30% remaining voltage (-70% sag) corrected to 95% of nominal
3 phase sags - to 60% remaining voltage (-40% sag) corrected to 95% of nominal
Output Regulation ±5% [Note: unit normally operates in bypass mode until voltage drops to a trigger point of 90% of nominal voltage, at which time correction is initiated]
Phase Shift Correction Phase shifts are corrected automatically during sag correction
Correction Duration No limitation on length or frequency of sag correction, no recharge time
Harmonic Distortion No distortion added in bypass mode
Surge Suppression
Surge Suppression Tested to ANSI/IEEE standard C62.41
Operating Characteristics
Overload/Inrush Capability 6000% -1 cycle, 1000% - 1 second, 500% - 5 seconds, 200% - 1 min. ; 1000% fault clearing
Minimum Load No minimum load
Load Power Factor No limitations, compatible with all load types
Response Time 2 milliseconds (1/8 cycle @ 60 Hz)
Efficiency 99% during normal operation
Operating Frequency Conforms to NERC standards
Unit/Load Protection
Circuit Breaker Input circuit breaker standard
Failsafe Electronic Bypass Actuates on overtemperature, overcurrent, component failure without loss of load
Construction
Technology Inverter-based series voltage injection
Enclosure NEMA 1 standard
Display Touchscreen display with event log, unit status, fault log
Cooling Natural convection (forced air cooling of inverter used in larger units)
Environmental
Audible Sound Level Meets NEMA standards
Ambient Temperature 32 to 104°F (0 to 40°C)
Relative Humidity 0-95% non-condensing
Operating Altitude 0 to 10,000 ft (3000m)
Common Options
Instrumentation Ammeter, voltmeter, power monitor with or without Modbus® communications capability
Adjustable Trigger Point Manually adjustable trigger point
Enclosures Enclosures NEMA 12, NEMA 3R, etc.  up to stainless steel NEMA 4X available
Maintenance Bypass Manual mechanical bypass to isolate unit

DVR Series Voltage Restorer, Deep Voltage Sag Corrector

Weights & Dimensions

Weights & Dimensions (standard 60 Hz units)
kVA Weight Dimensions – inches (cm)
  Lbs (kg) H W D
10 380 (172) 42 (107) 28 (71) 26(66)
20 420 (191) 42 (107) 28 (71) 26(66)
30 480 (218) 42 (107) 28 (71) 26(66)
50 550 (250) 42 (107) 28 (71) 26(66)
75 700 (318) 46 (117) 36 (91) 28 (71)
100 1000 (431) 46 (117) 36 (91) 28 (71)
150 1300 (499) 78 (198) 38 (97) 26 (66)
200 1600 (635) 78 (198) 78 (198) 26 (66)
250 2000 (817) 83 (211) 112 (284) 43 (109)
300 2400 (953) 83 (211) 112 (284) 43 (109)
400 3200 (1180) 83 (211) 112 (284) 43 (109)
500 4000 (1452) 83 (211) 112 (284) 43 (109)
> 500 Consult Factory

* Notes on weights and dimensions:
Standard three phase, 50 Hz units will weigh approximately 10% more than standard three phase, 60 Hz unit
Some options, particularly the mechanical bypass, may require a larger enclosure