PCVR Series Power Conditioner, Voltage Regulator


PCVR Series Power Conditioner, Voltage Regulator

Typical Specifications, Technical Data & Common Options

Application
Power Rating/Size (kVA) 5, 10, 15, 20, 25, 30, 50 75, 100, 150, 200, 250, 300, 400, 500 - up 2,000 kVA available
Phase - Frequency (Hz) Single phase or three phase - 50 or 60 Hz
Input/Output Voltages 120, 208, 220, 240, 380, 400, 440, 480, 600 typical.  Contact factory for other  voltages Any combination of step-up or step-down voltages up to 600v are available
Connections Delta input / Wye output standard – contact factory for other connection options
Cable Entry Side, back, top bottom, depending on enclosure type  – contact factory for details
Regulation/Operating Characteristics
Standard Regulation +10%/-25% input voltage range with output voltage regulated to ±3% of nominal
Optional Regulation ±10% input voltage range with output voltage regulated to ±2% of nominal
Regulation Variation None – regulation constant for 0 to 100% load and any load power factor
Overload/Inrush Capability 6000% -1 cycle, 1000% - 1 second, 500% - 5 seconds, 200% - 1 min. ; 1000% fault clearing
Minimum Load No minimum load or part load limitations
Load Power Factor No limitations, compatible with all load types
Tap Switching No load current interruption or waveform distortion on switching at any load or power factor
Zero Crossing Sensitivity Tap switching not dependent on determining load current zero crossing
Harmonic Distortion No distortion added at any load or power factor
Response Time 1 cycle typical regardless of load or load power factor
Efficiency 97% typical (autotransformer option 99%)
Operating Frequency ±3% of nominal frequency
Noise Suppression/Load Protection
Noise Attenuation 150 dB at 100 kHz common mode; 65 dB at 100 kHz normal mode (excluding autotransformer)
Surge Suppression Included, complies with ANSI/IEEE C62.41
Input Circuit Breaker Included, standard
Failsafe Electronic Bypass Auto-actuation on high temperature, over-current, component failure with no loss of load
Construction
Technology Electronically-controlled tap switching series transformer design
Switching Semiconductors Non-full power semiconductors – individual SCRs are not required to carry full unit current
Controls Microprocessor-based control
Cooling Natural convection, no cooling fans used
Isolation Transformer Shielded; meets ANSI specs
Enclosure NEMA 1 standard
Backlit LCD Display Phase regulation and status indicator
Environmental Requirements
Audible Sound Level Meets NEMA standards
Temperature - Humidity Ambient 32 to 104°F (0 to 40°C) – Relative humidity 0-95% non-condensing
Operating Altitude 0 to 10,000 ft (3000m)
Common Options
Instrumentation Ammeter, voltmeter, power monitor with or without Modbus® communications capability
Adjustable Output Voltage Manually adjustable output voltage setpoint (approx. ±10% of nominal voltage)
Maintenance Bypass Manual mechanical bypass to isolate unit
Autotransformer Autotransformer (non-isolated secondary) in lieu of isolation transformer
Enclosures Enclosures NEMA 12, NEMA 3R, etc.  up to stainless steel NEMA 4X available
Listings cULus available on common models - contact factory for specifics

Please call 800.876.9373 or email us . We can provide the technical assistance you need to select the proper Power Conditioner or UPS SYSTEM for your needs.

Weights & Dimensions

Weights & Dimensions (Standard 3 phase, 60 Hz units)*

kVA Rating

Weight

Dimensions – inches (cm)

 

Lbs (kg)

Height

Width

Depth

5

360 (164)

42 (107)

28 (71)

26(66)

10

400 (181)

42 (107)

28 (71)

26(66)

15

500 (226)

42 (107)

28 (71)

26(66)

20

600 (272)

42 (107)

28 (71)

26(66)

25

680 (308)

42 (107)

28 (71)

26(66)

30

750 (340)

42 (107)

28 (71)

26(66)

50

950 (431)

42 (107)

28 (71)

26(66)

75

1200 (544)

46 (117)

36 (91)

28 (71)

100

1600 (726)

46 (117)

36 (91)

28 (71)

125

1900 (862)

78 (198)

38 (97)

26 (66)

150

2200 (998)

78 (198)

38 (97)

26 (66)

200

2800 (1270)

78 (198)

78 (198)

26 (66)

250 (Vin≥380)

3300 (1497)

78 (198)

78 (198)

26 (66)

250 (Vin<380)

3500 (1588)

83 (211)

112 (284)

43 (109)

300

3800 (1724)

83 (211)

112  (284)

43 (109)

400

4400 (1996)

83 (211)

112  (284)

43 (109)

>400

Consult factory for details and options

* Notes on weights and dimensions:
Standard single phase, 60 Hz units will weigh approximately the same as the standard three phase, 60 Hz unit
Standard three phase, 50 Hz units will weigh approximately 10% more than standard three phase, 60 Hz unit
Standard single phase, 50 Hz units will weigh approximately 10% more than standard three phase, 60 Hz unit
Some options, particularly the mechanical bypass, may require a larger enclosure