Uniflair Chillers and Heat Rejection

Cooling Solutions | Schneider Electric Uniflair Series | Uniflair Chillers and Heat Rejection

The Schneider Electric Uniflair Chillers and Heat Rejection family of systems include air-cooled chillers, air-cooled condensers, and fluid cooled condensers. This family offers unmatched efficiency, flexibility and reliability.

Uniflair Chillers and Heat Rejection Range

  • Uniflair Air-Cooled Chillers
  • Uniflair Air-Cooled Condensers
  • Uniflair Fluid-Cooled Condensers

Uniflair Chillers and Heat Rejection

 

Schneider Electric Uniflair Chillers

Schneider Electric Uniflair Air-cooled Chillers, with axial fans for outdoor installation, are ideal for mission critical applications. This all-in-one integrated chilled water solution is the most efficient option for small, medium, large and extra-large data center environments. They combine cutting-edge technology with energy efficiency and environmental protection. All the units are all-in-one for easy design and installation and completely configurable to guarantee use in multiple applications and environmental conditions.

The large air side exchangers help reduce fan noise in the Air-Cooled Chillers, and along with the compressor insulation and housing, provide a quieter unit. This makes it a good fit for IT space in which excessive noise is an issue and gives you more flexibility in where it is placed.  The advanced control system constantly monitors set points to guarantee the unit always operates within operating limits and will signal any faults before breakdown occurs. These chillers support a wide range of applications and maximize the availability of Row and Room cooling products to provide a complete heat removal solution.

Uniflair Air Cooled Chillers Benefits

  • Single points of failure in the system have redundant components to maintain availability and reliability.
  • Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility.
  • Separate power input – Draws power from the external UPS for mainboards and heaters to monitor and protect the unit even in complete power failure mode (optional)
  • Continuous current monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).
  • Electronic expansion valve – Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring.
  • Active response control monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
  • Quick restart – Full load operation in less than 3 minutes with specific arrangements permits undersizing of the storage tanks
  • All the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while its in operation.
  • Easy service access – all serviceable components to be replaced/maintained by easily accessible panels/doors.
  • Operational Service – critical components to be maintained/replaced while the system is in operation.
  • Variable speed fans – Variable speed fans reduce energy consumption during off-peak cooling periods.
  • Integrated Hydronics Package – Includes all the necessary components to make one connection to the chiller without the need of external connections to auxiliary equipment such as pumps, increasing the speed of deployment.
  • Optimized management – Connection between the Computer Room Air Conditioners and the chillers guarantees energy efficiency, based on real instantaneous load conditions (optional)
  • Optimize the unit operation at any load or ambient condition, guaranteeing an extremely low power consumption.
  • Integrated pumps adjustment system – VSD onboard pumps are available for continuous adjustment of the chilled water loop available pressure. This provides automatic adjustments in Chilled water flow due to changes in cooling demand which ensures efficiency of the chilled water system. (Optional)
  • Tandem compressors – Quiet and efficient operation of compressors, connected on a common refrigerant circuit for staged capacity control (not available for some models/configuration)

For in-depth specifications, see the brochure.

Uniflair Chillers and Heat Rejection

Schneider Electric Uniflair Air Cooled Condensers

Schneider Electric Uniflair Air Cooled Condensers are specifically engineered heat rejection units for row and room cooling products. These condensers are system matched to maximize the availability of Row and Room cooling systems.

Uniflair Air Cooled Condensers provide a complete solution for small to medium data centers and are available with fixed and variable speed fans, these products support a wide range of applications.

Uniflair Air Cooled Condensers Features

  • Direct drive motors – Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
  • Variable speed fans -Variable speed fans reduce energy consumption during off-peak cooling periods.

Popular Models Include

ACCD75214: Condenser 1 Fan, Single Circuit, 2.4 MBH/1F TD, 230V/1/60
ACCD75215: Condenser 1 Fan, Single Circuit, 4 MBH/1F TD, 230V/1/60
 
 

Uniflair Chillers and Heat RejectionSchneider Electric Uniflair Fluid Coolers

Schneider Electric Uniflair Fluid Coolers offer heat removal that is designed to use water or glycol for cooling and is ideal for use in row and room cooling systems. Uniflair Fluid Coolers maximizes system availability and provides a complete solution for small to medium data centers. These products offer the flexibility to support a wide range of applications.

Uniflair Fluid Coolers Benefits

  • Direct drive motors – Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
  • Variable speed fans – Variable speed fans reduce energy consumption during off-peak cooling periods.

Popular Models Include

ACFC75210: Fluid Cooler 135MBH@25TD, 30 GPM, 16 Feeds, 460/3/60
ACFC75255: Fluid Cooler 59MBH@25TD, 10 GPM, 8 Feeds, 480/3/60

For more information about Schneider Electric Cooling,
call 800-876-9373 or email sales@power-solutions.com.