Server Technology – Metered Rack PDU

Cabinet Power Distribution with Branch Circuit Protection, and Local Input Current Monitoring

server tech metered PDUHigh Density Power Distribution

Increasing power demands and density in the equipment cabinet requires new functionality from your cabinet PDU.  The Sentry Cabinet Power Distribution Unit is a PDU with local LED input current monitoring, allowing network engineers to utilize the PDU’s True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit.  As new servers and devices are added to the power drop, immediately observe its impact on the cumulative current draw.  This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit.

Server Technology Sentry Metered PDUs include the following features:

Flexible Mounting Options – Zero-U button or bracket mounting for mounting vertical PDUs in the back or on the side of the cabinet to avoid consuming valuable U space.

Branch Circuit Protection All Sentry PDUs meet the UL 60950-1 requirement for branch circuit protection and use either fuses or circuit breakers to protect each branch of outlets.

Input Current Monitoring – The PDU’s exclusive True RMS Current Monitoring is critical to preventing overloads in high-density computing environments.  Digital LED displays on the PDU enclosure report the input current of each phase or branch circuit.

Cable Retention Clip – Ensures power cords to the connected devices are not accidentally unplugged or disconnected.

Popular Models Include:

This list represents a small portion of the Metered Server Technology PDUs available.
For assistance with configuration or pricing, please contact us.

100V – 120V Single Phase Input

C-10H1 – Horizontal 1U Rack PDU, 2.4 kW or 3.6kW, 20A or 30A, 100-120V, (10) 5-20R
C-24V1 – Zero-U Vertical PDU, 2.4kW or 3.6 kW, 20A or 30A, 100-120V, (24) 5-20R

208V – 240V Single Phase Input

C-4H2 – Horizontal 1U Rack PDU, 4.2kW or 6.2kW, 20A or 30A, 208-240V, (4)
C19C-4HD – Horizontal 2U Dual Input Rack PDU, 4.2kW or 6.2kW, 20A or 30A, 208-240V, (4) C19
C-12H2 – Horizontal 1U Rack PDU, 4.2kW or 6.2kW, 20A or 30A, 208-240V, (12) C13
C-24H2 – Horizontal 1U Rack PDU, 6.2kW, 30A, 208-240V, (24) C13
C-30V2 – Zero-U Vertical Rack PDU, 4.2kW or 6.2kW, 20A or 30A, 208-240V, (24) C13 + (6) C19

208V – 240V 3-Phase Input

C-24VD / Y-001 – Zero-U Vertical PDU, 7.2kW or 10.8kW, 20A or 30A, 3-Phase 208-240V, (24)
C13C-24VD / Y-A9 – Zero-U Vertical PDU, 18kW or 21.6kW, 50A or 60A, 3-Phase 208-240V, (12) C13 + (12) C19
C-48V5 – Zero-U Vertical PDU, 14.4kW or 21.6kW, 20A or 30A, 3-Phase 208-240V, (48) C13