The Power Experts

Server Technology – Smart PDU

Cabinet Power Distribution with Branch Circuit Protection, expanded functionality of SNMP-based Input Current Monitoring and Environmental Monitoring

Server Tech smart PDUHigh Density Power Distribution

The Smart Cabinet Power Distribution Units (PDU) provide reliable power distribution combined with local and remote power monitoring and environmental monitoring via IP.  Use the network interface to view power, temperature and humidity levels via Web browser, or receive SNMP-based alarms and email alerts when conditions exceed defined thresholds.

The Smart PDU Family has the capability to daisy chain units together.  The expansion PDU module gives the ability to use one IP address across different power circuits.

Server Technology Sentry Smart PDUs include the following features:

Flexible Mounting Options – Zero-U button or bracket mounting for mounting vertical PDUs in the back or on the side of the cabinet to avoid consuming valuable U space.

Branch Circuit Protection All Sentry PDUs meet the UL 60950-1 requirement for branch circuit protection and use either fuses or circuit breakers to protect each branch of outlets.

Input Current Monitoring – The PDU’s exclusive True RMS Current Monitoring is critical to preventing overloads in high-density computing environments.  Digital LED displays on the PDU enclosure report the input current of each phase or branch circuit.

Environmental Monitoring – External probes, with 3-meter cable, capable of measuring temperature & humidity.  Receive SNMP-based or email alerts when conditions exceed defined thresholds.

Expansion Module – Our exclusive method for linking additional outlets, on separate PDU’s, together under a single IP address, and provides support for A&B power in-feeds.

IP Access, Security & Communications – Web interface, SSL, SSH, Telnet, SNMP & RS-232 access, 10/100 Base T-Ethernet, SSLv3/TLSv1, SNMPv2, TACACS+, LDAP, LDAPS, RADIUS, DHCP, SMTP/Email, & Syslog.

Cable Retention Clip – Ensures power cords to the connected devices are not accidentally unplugged or disconnected.

Per Inlet Power Sensing (PIPS) – Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor, Reactance, Accumulated energy (kWh), and Power factor per inlet.  PIPS is available on select Smart and Switched PDU’s.

Per Outlet Power Sensing (POPS) – Monitor Current Load (A), Voltage (V), Power (W), Apparent Power (VA), Crest Factor and Power Factor per outlet.  POPS is available on select Smart and Switched PDU’s.

Popular Models Include:

This list represents a small portion of the Smart Server Technology PDUs available.
For assistance with configuration or pricing, please contact us.

100V – 120V Single Phase Input

CS-2HD1 – Horizontal 1U Smart Power Monitor, 4.8kW, 20A, 100-120V, C19
CS-16V1-MX – Zero-U Vertical PDU, 2.4kW, 20A, 100-120V, (16) 5-20R
CS-16V1 – Zero-U Vertical PDU, 2.4kW or 3.6kW, 20A or 30A, 100-120V, (16) 5-20R
CS-24V1 – Zero-U Vertical PDU, 2.4kW or 3.6kW, 20A or 30A, 100-120V, (24) 5-20R

208V – 240V Single Phase Input

CS-2HD2 – Horizontal 1U Smart Power Monitor, 8.4kW, 20A, 208-240V, C19
CS-2HD2 – Horizontal 1U Smart Power Monitor, 12.4kW, 30A, 208-240V, L6-30R
CS-12HD2 – Horizontal 2U Rack Mount PDU, 4.2kW or 6.2kW, 20A or 30A, 208-240V, (12) C19
CS16V2-MX – Zero-U Vertical PDU, 4.2kW, 20A, 208-240V, (16) C13
CS-16V2 – Zero-U Vertical PDU, 4.2kw or 6.2kW, 20A or 30A, 208-240V, (16) C13
CS-24V2 – Zero-U Vertical PDU, 4.2kW or 6.2kW, 20A or 30A, 208-240V, (24) C13
CS-24V2-8C1 – Zero-U Vertical PDU, 4.2kW or 6.2kW, 20A or 30A, 208-240V, (18) C13 + (6) C19, 37U
CS-24V2-MA – Zero-U Vertical PDU, 4.2kW or 6.2kW, 20A or 30A, 208-240V, (18) C13 + (6) C19, 40U
CS-30V2 – Zero-U Vertical PDU, 4.2kW or 6.2kW, 20A or 30A, 208-240V, (24) C13 + (6) C19
CS-36V2 – Zero-U Vertical PDU, 12.4kW, 60A, 208-240V, (30) C13 + (6) C19

208V – 240V 3-Phase Input

CS-2HDD / Y – Smart Power Monitor, Horizontal, 1U, 14.4kW or 21.6kW, 20A or 30A, 3-Phase 208-240V, L15 or L21
CS-2HDD 50A / 60A – Smart Power Monitor, Horizontal, 1U, 36kW or 43.2kW, 50A or 60A, 3-Phase 208-240V, CS8364C or IEC 60309 Delta
CS-4HD / HY – Horizontal 2U Rack Mount PDU, 18kW or 21.6kW, 50A or 60A, 3-Phase 208-240V, (4) NEMA L15-30R
CS-6HD / HY – Horizontal 2U Rack Mount PDU, 18kW or 21.6kW, 50A or 60A, 3-Phase 208-240V, (6) NEMA L6-30R
CS-12HDD / Y – Horizontal 2U Rack Mount PDU, 7.2kW or 10.8kW, 20A or 30A, 3-Phase 208-240V, (12) C19
CS012HD / Y-C8 – Horizontal 2U Rack Mount PDU, 7.2kW or 10.8kW, 20A or 30A, 3-Phase 208-240V, (6) C13 + (6) C19
CS-12HD-A3 – Horizontal 2U Rack Mount PDU, 18kW or 21.6kW, 50A or 60A, 3-Phase 208-240V, (12) C19
CS-15HD / Y – Horizontal 2U Rack Mount PDU, 18kW or 21.6kW, 50A or 60A, 3-Phase 208-240V, (12) C19 + (3) C13
CS-18V-A3 – Zero-U Vertical PDU, 18kW or 21.6kW, 50A or 60A, 3-Phase 208-240V, (18) C19
CS-24VD / VY – Zero-U Vertical PDU, 10.8kW, 30A, 3-Phase 208-240V, (24) C13
CS-24VD / VY-MA – Zero-U Vertical PDU, 10.8kW, 30A, 3-Phase 208-240V, (18) C13 + (6) C19
CS-24VD / VY 12×12 – Zero-U Vertical PDU, 18kW or 21.6kW, 50A or 60A, 3-Phase 208-240V, (12) C19 + (12) C13
CS-27VY – Zero-U Vertical PDU, 10.8kW, 30A, 3-Phase 208-240V, (6) 5-20R + (21) C13
CS-27VY-423 – Zero-U Vertical PDU, 7.2kW or10.8kW, 20A or 30A, 3-Phase 208V, (21) 5-20R + (6) L6-20R
CS-3AVY – Zero-U Vertical PDU, 7.2kW or 10.8kW, 20A or 30A, 3-Phase 208-240V, (12) 5-20R + (9) C13 + (9) C19
CS-36VD / VY – Zero-U Vertical PDU, 10.8kW, 30A, 3-Phase 208-240V, (36) C13
CS-36VD / Y-A4 – Zero-U Vertical PDU, 7.2kW or 10.8kW, 20A or 30A, 3-Phase 208-240V, (24) C13 + (12) C19
CS-42VD / Y – Zero-U Vertical PDU, 7.2kW or 10.8kW, 20A or 30A, 3-Phase 208-240V, (42) C13
CS-48VDD / VD-A1 – Zero-U Vertical PDU, 18kW or 21.6kW, 50A or 60A, 3-Phase 208-240V, (36) C13 + (12) C19

240V/415V 3-Phase Input

CS-6H5 – Horizontal 2U Rack Mount PDU, 14.4kw or 21.6kw, 20A or 30A, 3-Phase 240/415V, (6) NEMA L6-30R
CS-24H5 – Horizontal 3U Rack Mount PDU, 14.4kW or 21.6kW, 20A or 30A, 3-Phase 240/415V, (18) C13 + (6) C19
CS-18V5 – Zero-U Vertical PDU, 14.4kW or 21.6kW, 20A or 30A, 3-Phase 240/415V, (18) C19
CS-24VS-A9 – Zero-U Vertical PDU, 14.4kW or 21.6kW, 20A or 30A, 3-Phase 240/415V, (12) C13 + (12) C19
CS-24V5-A3 – Zero-U Vertical PDU, 43.2kW, 60A, 3-Phase 240/415V, (24) C19
CS-36V5-A4C – Zero-U Vertical PDU, 14.4kW or 21.6kW, 20A or 30A, (24) C13 + (12) C19

415V 3-Phase Input

CS-2HS 415V – Smart Power Monitor, Horizontal, 1U, 14.4kW or 21.6kW, 20A or 30A, 3-Phase 415V, L22-30P or IEC 60309 Wye

For assistance with configuration or pricing, please contact us.  1-800-876-9373