1.800.876.9373

Toshiba EL924 Series UPS

UPS Systems | Emergency Lighting Inverters | Toshiba EL924 Series UPS

Toshiba EL924 Series UPSThe Toshiba EL924 Series UPS, 15 and 20 kVA, by Toshiba, is a solution for UL 924 requirements of power equipment for emergency lighting. Emergency Lighting AC LED fixtures require a true sine wave to operate properly as opposed to the modified square waves that are prevalent in many single conversion inverters. Using a large, three-phase, centralized UPS allows for larger sections of emergency lighting to be backed up so that maintenance of battery and equipment is localized to a single system.

The EL924 Series system features double-conversion, all insulated-gate bipolar transistors with an easy to navigate local touchscreen interface. State-of-the-art electronic battery isolation circuitry and a robust DC capacitor bank ensure battery longevity, reducing total cost of ownership. The small footprint and total front access mechanical design allows zero rear clearance for reduced site space requirements. The flexibility of top, bottom, and/or side cable entry adds to the ease of installation. The EL924 Series system also comes standard with Toshiba’s RemotEye® 4 multi-protocol UPS manager that provides centralized remote monitoring by utilizing protocols such as Modbus TCP & RTU, BACnet IP & MSTP, HTTP/HTTPS, and SNMP.

The EL924 Series system is a Houston-built UPS cabinet with matching battery cabinets to provide 90-minute runtime as required per UL 924, while keeping to UL 1778 requirements and the Buy American Act of domestic end products.

Toshiba EL924 Series UPS Features

  • High Efficiency
  • Easily Installed
  • 3-Year Onsite Warranty
  • 0.9 Power Factor
  • Small Footprint
  • Made in the U.S.A.
  • Voltage ratings of 208/380/400/415/480 Vac in/out

EL924 Series UPS Specifications

Capacity15kVA (13.5kW)20kVA (18kW)
TopologyTrue On-Line Double Conversion UPS
CertificationUL924, UL1778, ANSI C62.41 (IEEE 587), Buy American Act
INPUT 
Voltage (VAC)208/380*/400*/415*/480*/600*
Voltage Range+10%, -15% at full load,+10%, -30% at 70% load
Capacity (VA)1500020000
Capacity (W)1350018000
Frequency (HZ)50/60 Auto-Sensing
Frequency Range (HZ)45 – 65
Power Factor0.97
OUTPUT 
Voltage208/380**/400**/415**/480**
Voltage Regulation+/- 1% nominal (balanced load)
Frequency60 Hz, ±1%
Power Factor0.9
Operating Temp32 to 104 F (20 to 40 C)

For more in-depth information, see the data sheet.

 

For more information about Toshiba UPS,
call 800-876-9373 or email [email protected].