Tripp Lite Monitored PDU

Tripp Lite Monitored PDUTripp Lite Monitored PDU (Power Distribution Unit) offers reliable in-rack power distribution and remote power monitoring for single or three-phase units in data centers, server rooms, and network wiring closets. The metered PDU tracks voltage, frequency, and load levels in real-time using a built-in network connection. Output current consumption is displayed locally on a visual meter to warn of potential overloads.

Connecting additional equipment to a PDU can overload it or the supply circuit, causing breakers to trip or equipment to fail. Both metered and monitored PDUs display load levels in real-time, allowing additional equipment to be connected safely. The primary input plugs into an on-line UPS and the secondary input plugs into a wall outlet. If the UPS system is taken offline for maintenance, repair or replacement, the ATS in the PDU keeps the load powered by automatically switching from the primary input to the secondary input. When the UPS system is restored, the PDU will switch back to the primary input.

Some Monitored models have an automatic transfer switch that provides redundant power sources. An Automatic Transfer Switch PDU automatically switches to a secondary power source if power fails or is switched off for maintenance. The dual AC inputs can be connected to two utility sources, two generator sources, two UPS sources or any combination. With single and 3-phase, vertical and horizontal options, and ranges from 1.4kW to 18.7kW, Tripp Lite has the monitored PDU model that will fit your application.

Tripp Lite Monitored PDU Models

PDUMNH20 – 1.9kW Single-Phase, Horizontal, 1U, 120V, Outlets (8) 5-15/20R, 12 ft. Cord, LX Platform Interface, TAA
PDUMNV30HVLX – 5/5.8kW Single-Phase, Vertical, 0U, 208/240V, Outlets (36) C13 & (6) C19, LX Interface, 10 ft. Cord, TAA
PDUMNH15 – 1.4kW Single-Phase, Horizontal, 1U, 120V, Outlets (8) 5-15R, LX Platform Interface, 12 ft Cord, TAA
PDUMNV20LX – 1.9kW Single-Phase, Vertical, 0U, 20V Outlets (24) 5-15/20R, LX Platform Interface, TAA
PDUMNH20HV – 3.2-3.8kW Single-Phase, Horizontal, 1U, 208/220/230/240V, Outlets (8)C13, 8 ft Cord, TAA Compliant
PDU3EVN10G60B – 14.5kW 3-Phase, Vertical, 0U, 208/240V, Outlets (42) C13 & (6) C19, LCD, LX Interface, 3m/10 ft. Cord, TAA
PDUMNV30HVLX – 5/5.8kW Single-Phase, Vertical, 0U, 208/240V, Outlets (20) C13 & (4) C19, LX Platform Interface, TAA
PDUMNV30LX – 2.9kW Single-Phase,  Vertical, 0U, 120V, Outlets (24) 5-15/20R, LX Platform Interface, TAA
PDUMNH30HV – 5/5.8kW Single-Phase, Horizontal, 2U, 208/240V, Outlets (12) C13 & (4) C19, LX Platform Interface, 12 ft Cord, TAA
PDUMNH30 – 2.9kW Single-Phase, Horizontal, 2U, 120V, Outlets (16) 5-15/20R, 10 ft. Cord, TAA
PDU3VN10L2120LV – 5.7kW 3-Phase, Vertical, 0U, 120V, Outlets (36) 5-15/20R, 10 ft Cord, TAA
PDUMNV32HV2LX – 7.4kW Single-Phase, Vertical, 0U, 230V, Outlets (36) C13/6 C19, LX Interface, 10 ft. Cord, TAA
PDUMNV15LX – 1.4kW Single-Phase, Vertical, 0U, 120V, Outlets (16) 5-15R, LX Platform Interface, 10 ft. Cord with 5-15P Plug, TAA
PDUMNV20HVLX – 3.3–3.7kW Single-Phase, Vertical, 0U, 208/230V, Outlets (20) C13 & (4) C19, LX Platform Interface, TAA
PDUMNH32HV – 7.4kW Single-Phase, Horizontal, 2U, 230V, Outlets (12) C13 & (4)C19, LX Platform Interface, 12 ft Cord, TAA
PDUMNH30HVAT – 5.8kW Single-Phase Monitored Automatic Transfer Switch, Horizontal, 1U, 2 208/240V, Outlet (1) L6-30R
PDU3EVN10L2130 – 8.6kW 3-Phase, Vertical, 0U, 208/120V, Outlets (3) 5-15/20R & (36) C13 &(6) C19, LCD, LX Interface, 3m/10 ft. Cord, TAA
PDU330AT6L2130 – 8.6kW 3-Phase Monitored Automatic Transfer Switch, Horizontal, 1U, 2 208V
PDUMNH16HVAT – 3.7kW Single-Phase Monitored Automatic Transfer Switch, Horizontal, 1U, 2 230V,  Outlets (1) IEC309
PDU3EVN10L1530B – 10kW 3-Phase, Vertical, 0U, 208/240V, Outlets (4) C13 & (6) C19, LCD, LX Interface, 3m/10 ft. Cord, TAA
PDU3EVN6G60C – 18.7kW 3-Phase, Vertical, 0U, 208/240V, Outlet (36) C13, LX Platform, TAA
PDU3VN10H50 – 14.5kW 3-Phase, Vertical, 0U, 200/208/240V, Outlets (42) C13 & (6) C19, 10 ft. Cord, TAA
PDU330AT6L1530 – 8.6kW 3-Phase Monitored Automatic Transfer Switch, Horizontal, 1U, 2 208V L15-30P, Outlets C13 and C19
PDU3EVN6L2120 – 5.8kW 3-Phase, Vertical, 0U, Outlets (36) C13 &(6) C19 & (3) 5-15/20R
PDUMNV20HV2LX – 3.3/3.7kW Single-Phase, Vertical, 0U, 208/230V, Outlets (18) C13 & (2) C19, LX Platform Interface, TAA
PDU3EVN6L2130 – 8.6kW 3-Phase, Vertical, 0U, 208/120V, Outlets (36) C13 & (6) C19 & (3) 5-15/20R, LCD, LX Interface, 1.8m/6 ft. Cord, TAA
PDU3EVN6L2130B – 10kW 3-Phase, Vertical, 0U, 208/240V, Outlets (42) C13 & (6) C19, LCD, 1.8m/6 ft. Cord, LX Interface, TAA
PDU3EVNR6G60A – 16.2kW 3-Phase,  Vertical, 0U, 208/240V, Outlets (12) C19 &(6) C13, LX Platform, TAA
PDUMNH20HVAT – 3.8kW Single-Phase Monitored Automatic Transfer Switch, Horizontal, 1U, 2 208/240V, OUtlets (1) L6-20R
PDU3XVN6G20 – 11.5kW 3-Phase, Vertical, 0U, 200/220/230/240V, Outlets (42) C13 & (6) C19, 360-415V input, TAA
PDU3EVN6G60B – 14.5kW 3-Phase, Vertical, 0U, 208/240V, Outlets (42) C13 & (6) C19, LCD, LX Interface, 1.8m/6 ft. Cord, TAA
PDU3EVN6H50B – 14.5kW 3-Phase, Vertical, 0U, 208/240V, Outlets (42) C13 & (6) C19, LCD, 1.8m/6 ft. Cord, LX Interface, TAA
PDU3EVN6H50BA – 14.5kW 3-Phase, Vertical, 0U, 208/240V, Outlets (30) C13 & (12) C19, LX Platform, TAA
PDUMNH32HVAT – 7.4kW Single-Phase Monitored Automatic Transfer Switch PDU, Horizontal, 1U, 2 230V, Outlet IEC309 32A BLUE (2P+E)
PDU3EVN10L2130B – 10kW 3-Phase, Vertical, 0U, 208/240V, Outlets (42) C13 & (6) C19, LCD, 3m/10 ft. Cord, LX Interface, TAA
PDU3VN6L2130B – 10kW 3-Phase, Vertical, 0U, 200/208/240V, Outlets (42) C13 & (6) C19, 6ft Cord, TAA
PDU3EVN3L2130B – 10kW 3-Phase, Vertical, 0U, 208/240V Outlets (42) C13 & (6) C19, LCD, 1m/3 ft. Cord, LX Interface, TAA
PDU3EVN6L1520 – 6.6kW 3-Phase, Vertical, 0U, 208/240V, Outlets (42) C13 & (6) C19, LX Platform, TAA
PDU3XVN10G16 – 11kW 3-Phase, Vertical, 0U, 220/230V, Outlets (30) C13 & (6) C19, 380/400V Input, 10ft Cord
PDU3EVN10H50B – 14.5kW 3-Phase, Vertical, 0U, 208/240V, Outlets (42) C13 & (6) C19, LCD, 3m/10 ft. Cord, LX Interface, TAA
PDU3EVN6G30B – 10kW 3-Phase, Vertical, 0U, 208/240V, Outlets (42) C13 & (6) C19, LCD, 1.8m/6 ft. Cord, LX Interface, TAA
PDU3VN6G30B – 10kW 3-Phase, Vertical, 0U, 200/208/240V, Outlets (42)C13 & (6)C19, 6ft Cord, TAA
PDU3XVN3G16 – 11kW 3-Phase, Vertical, 0U, 220/230V, Outlets (30) C13 & (6) C19, 380/400V Input, 3ft Cord
PDU3XEVN6G20 – 11.5kW 3-Phase, Vertical, 0U,  380/400/415V, Outlets (42) C13 & (6) C19, LX Platform, TAA
PDU3VN3G30 – 10kW 3-Phase, Vertical, 0U, 200/208/240V, Outlets (42) C13 & (6) C19, 3 ft. Cord, TAA
PDU3EVNR6H50A – 14.4kW 3-Phase, Vertical, 0U, 208V, Outlets (6) C13 & (12) C19, LX Platform, TAA
PDU3EVNR6L1530 – 10kW 3-Phase, Vertical, 0U, 208/240V, Outlets (24) C13 & (6) C19, LX Platform, TAA
PDU3EVNR6L2130 – 10kW 3-Phase, Vertical, 0U, 208/240V, Outlets (24) C13 & (6) C19, LX Platform, TAA
PDU3EVNR6H50 – 14.5kW 3-Phase, Vertical, 0U, 208/240V, Outlets (24) C13 & (6) C19, LX Platform, TAA

For more information about Tripp Lite Monitored PDUs,