Schneider Electric Uniflair Free Cooling Chillers are an all-in-one integrated chilled water solution for data center cooling.
Free-cooling air cooled chillers leverages external air to remove the heat. These chillers reduce energy consumption compared to traditional systems. Aquaflair FC units are featured with embedded free-cooling, without increasing product footprint or clearances. All of Schneider Electric’s Aquaflair Chillers offer low noise impact through the use of large air side heat exchangers, controlling fan rotation and insulated compressor section of the chiller. The advanced control system constantly monitors set points to guarantee the unit always operates within operating limits and will signal any faults before breakdown occurs.
These chillers support a wide range of applications and maximize the availability of Row and Room cooling products to provide a complete heat removal solution.
Schneider Electric Uniflair Free Cooling Chillers Features
- Quick restart – Full load operation in less than 3 minutes with specific arrangements permits undersizing of the storage tanks
- Separate power input – Draws power from the external UPS for mainboards and heaters to monitor and protect the unit even in complete power failure mode (optional)
- Redundant Components – Single points of failure in the system have redundant components to maintain availability and reliability
- Integrated free-cooling – Allows continuous operation in winter mode even with compressor failure
- Continuous current monitoring – Permits a continuous monitoring of the compressor’s absorbed current to signal possible discrepancies with the default values (Optional).
- Electronic expansion valve – Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring
- Active response control – Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided
- Building management system integration – Send alarms and data points allowing you to manage critical building infrastructure from a single system.
- Network interface – Provides management by connecting the device directly to the network with a dedicated IP address. Management is available via Web browser, Telnet or SSH.
- Easy service access
- Modular design of the mechanical and control systems allows for gradual build-up of the cooling infrastructure to match the cooling demand of the facility.
- Quiet and efficient operation of compressors, connected on a common refrigerant circuit for staged capacity control (not available for some models/configuration)
- Integrated Hydronics Package – Includes all the necessary components to make one connection to the chiller without the need of external connections to auxiliary equipment such as pumps, increasing the speed of deployment.
- Integrated pumps adjustment system – (Optional) VSD onboard pumps are available for continuous adjustment of the chilled water loop available pressure. This provides automatic adjustments in Chilled water flow due to changes in cooling demand which ensures efficiency of the chilled water system.
For more information about Schneider Electric Cooling,
call 800-876-9373 or email [email protected].