Uniflair Small Room Cooler

Uniflair Small Room CoolerThe Schneider Electric Uniflair Small Room Cooling units, with a cooling capacity range 5-20kW, offer high performance cooling for small data centers and Edge cooling applications that require 24/7 reliability. Available in direct expansion air cooled units, direct expansion water cooled units and chilled water units.

  • Direct Expansion Air Cooled units (SDAV-SUAV) are highly efficient mechanical cooling systems that can be coupled with wide range of remote air-cooled condensers and employ to the latest generation of compressors.
  • Direct Expansion Water Cooled units (SDWV-SUWV) provide efficient cooling solutions, even in environments with limited outdoor space. These units leverage existing water sources (like cooling towers or city water) to condense the refrigerant, requiring only a dry cooler, allowing for installation in various locations without distance constraints.
  • Chilled Water units (SDCV-SUCV) are designed to work with a centralized chilled water plant, offering efficient and scalable cooling solutions even for large data centers and facilities.

Uniflair Small Room Cooler Features

  • Direct drive motors – Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
  • Multi-functional Microprocessor Controller – Allows the units to restart after a power failure without intervention; Allows for room level redundancy with up to ten units operating in a group; User friendly navigation with icon based displays to indicate mode of operation as well as room conditions; Allows for communication with multiple Building Management System protocols.
  • Active response control – Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and status of the unit is provided.
  • Redundant Components – Single points of failure in the system have redundant components to maintain availability and reliability.
  • Heat Rejection Configurations – Available in air-cooled, water-cooled, and chilled water systems
  • Service monitoring – All the monitoring devices on board the unit allow for preventive maintenance and a check of the working condition of the system while it’s in operation.
  • Operational Service – Allows critical components to be maintained/replaced while the system is in operation.
  • Complete front serviceability – Enables all maintenance of the unit through front access.
  • High performance technological solutions – Optimize the unit operation at any load or ambient condition, guaranteeing an extremely low power consumption
  • Automatic Floor Pressurization System – Ensures stable airflow pressurization under floor regardless of changes made above the floor
  • Modular strategy – Modular design of the mechanical and control systems allow for gradual build-up of the cooling infrastructure to match the cooling demand of the facility. This greatly reduces CAPEX expediture and provides deferred investment throughout the life of the facility.
  • Electronically Commutated Fans – Provide the highest efficiency and reduce total power consumption by matching the airflow requirements to the heat load of the data center.

For specifications and more in-depth information, see the brochure.