Engineering Challenges of UPS Systems with Runtimes Exceeding 24 Hours

Industry Trends | Engineering Challenges of UPS Systems with Runtimes Exceeding 24 Hours

Engineering Challenges of UPS Systems with Runtimes Exceeding 24 HoursUninterruptible Power Supply (UPS) systems play a vital role in ensuring operational continuity in settings where power disruptions could result in substantial financial setbacks, data loss, or safety hazards. Although conventional UPS designs emphasize short-term backups, usually lasting 5 to 15 minutes to allow time for generators to engage, the escalating requirements of edge computing, isolated facilities, and essential applications are extending these boundaries to runtimes surpassing 24 hours. As critical infrastructure facilities face growing risks of sustained power outages, the demand for Uninterruptible Power Supply (UPS) systems capable of delivering extended runtimes—often exceeding 24 hours—continues to rise. These systems, however, introduce a range of technical and economic challenges that surpass the scope of conventional UPS configurations.

This article explores the complex design considerations involved in creating long-duration UPS solutions, including the scalability of energy storage, inverter charging limitations, thermal management, safety compliance, and return on investment (ROI). By leveraging industry knowledge, it demonstrates how these issues can be tackled with creative designs and cutting-edge technologies.

Power Solutions, LLC, recognized as the premier supplier of long-runtime UPS solutions, demonstrates unparalleled skill in providing customized, vendor-neutral turn-key systems in sectors such as IT, manufacturing, and telecommunications. Power Solutions LLC addresses the challenges of extended runtimes by engineering integrated systems comprised of custom battery banks, dedicated charging systems, and properly sized inverter architectures.

Engineering Challenges of UPS Systems with Runtimes Exceeding 24 Hours Introduction

In today’s digital evolution, the dependability of power systems is more crucial than ever. UPS systems act as the primary safeguard against outages, enabling smooth shifts to reserve power. Yet, as businesses venture into mission-critical distant or peripheral sites, like edge data centers, hospitals, defense installations, and remote operations, the demand for UPS runtimes over 24 hours grows indispensable. Such durations support ongoing activities amid extended blackouts, pending grid recovery or local fixes. Traditional UPS models favor limited durations, typically synced with generator activation periods. Designing UPS systems for such extended runtimes is not merely a matter of scaling battery capacity. It requires a comprehensive re-engineering of system components and infrastructure. This includes overcoming constraints in battery size and weight, inverter charging limitations, space planning, heat dissipation, and compliance with stringent regulatory standards. This document explores these hurdles, delivering guidance for engineers, site overseers, and policymakers. Power Solutions, LLC emerges as an innovator, utilizing alliances with more than 20 manufacturers to develop answers that confront these needs directly.

The Demand for Extended Runtime UPS

The movement toward prolonged UPS runtimes can be attributed to various influences. The spread of edge computing involves dispersed IT setups in secluded spots that frequently require independent power that can last hours or even days. Essential infrastructure in areas like healthcare, banking, and public services needs constant power to avert disastrous breakdowns, where even brief interruptions may result in millions of dollars in losses, or even risk lives. Heightened emphasis on emergency readiness also enforces extended reserves for adherence and functional stability. Notwithstanding these necessities, most UPS configurations are tuned for quick surges, with durations figured at 80% battery level to factor in deterioration. Advancing past 24 hours intensifies core restrictions, demanding a reevaluation of fundamental elements.

Engineering Challenges

Crafting UPS systems for exceptionally long runtimes entails diverse obstacles across fields like materials engineering, electrical design, and overall structure.

Battery Technology and Capacity

Batteries form the core of any UPS, yet expanding for 24-plus hours requires enormous capacity boosts, frequently entailing bigger arrays or sophisticated compositions such as lithium-ion instead of lead-acid. Batteries deteriorate gradually, shedding capacity from reactions, heat variations, and usage cycles. For extended durations, configurations must feature anticipatory oversight to swap parts pre-failure, since decline might cut usable time by 20% or greater.

As battery systems grow in scale, so too does the complexity of managing them. Large energy storage systems require advanced Battery Management Systems (BMS) to ensure proper cell balancing, monitor temperatures, and track lifecycle data. Poorly managed systems risk performance degradation and, in extreme cases, pose safety hazards. Effective BMS platforms are essential for scheduling maintenance, detecting faults, and maximizing service life.

Battery Weight and Size Constraints

Achieving 24 or more hours of runtime necessitates a significant increase in energy storage capacity. Traditional lead-acid batteries, while cost-effective, become increasingly impractical at scale due to their considerable weight and spatial demands. Although lithium-ion batteries offer a higher energy density and are more compact, they still require substantial thermal management and installation space. Many facilities lack the structural support or square footage to accommodate these systems without extensive and costly retrofitting.

Larger capacities lead to heftier arrangements, posing difficulties in confined spaces. Spread-out battery layouts can ease this by distributing burdens, albeit adding cable intricacies and possible weak spots. Extended releases hazard deep draining, hastening deterioration, so plans need refined charge regulators to avert excess depletion while embedding rapid recharging for green sources.

Thermal Management

High-capacity UPS systems generate considerable heat, particularly when operating continuously for long durations. Effective thermal management—including upgraded HVAC systems, active cooling mechanisms, and thermal monitoring—is essential to maintain performance and prevent overheating. Lithium-ion chemistries, while efficient, are especially susceptible to thermal runaway if not adequately cooled, necessitating even stricter control measures.

Efficiency and Power Losses

Performance wanes as duration lengthens, with transformation deficits (AC-DC-AC) accumulating over time. Potent designs should curb exchange deficits, commonly via silicon carbide (SiC) elements for superior output.

Compressing greater capacity into tinier areas heightens concentration but worsens deficits and warmth. Surge flows from gear initiations mandate oversized parts, diminishing total performance. Refining for over 95% performance is key to prolong feasible duration without drastic cost hikes.

Inverter and Charging Limitations

One of the most overlooked limitations in long-duration UPS systems lies in the charging capacity of inverters. Commercial UPS inverters are typically optimized for short-duration support and often feature restricted charging current capabilities. As battery banks scale, insufficient charging capacity can lead to excessively long recharge cycles—sometimes longer than the runtime itself. This delay undermines system readiness and increases vulnerability to subsequent outages. Overcoming this bottleneck requires the incorporation of independent, purpose-built battery chargers capable of replenishing energy reserves efficiently and reliably.

System Reliability and Redundancy

Prolonged durations raise the risks for malfunctions, where one flaw might trigger widespread halts. Ventilators, condensers, and incorporated generators rank as frequent vulnerabilities. Backup plans (like N+1) bolster toughness but boost expenses. Neglect in care, such as omitting cell checks, persists as a primary malfunction trigger. Merging with generators or greens demands exact rate syncing to prevent falls. Segmented structures enable component swaps without downtime, boosting availability.

Scalability and Modularity

Expanding for 24-plus hours typically involves segmented growths, yet this brings alignment problems among parts. Preparing for expansion requires adaptable layouts, such as scattered versus unified cells, with the prior providing superior error separation.

Regulatory and Safety Compliance

Extended-runtime UPS systems are subject to rigorous regulatory scrutiny. Fire codes such as NFPA 855 and standards such as UL 9540 and UL 9540A impose strict requirements on energy storage system design, particularly regarding fire suppression, spacing, ventilation, and containment. In many jurisdictions, energy storage capacities are capped or subject to complex permitting procedures. Compliance with these evolving standards is non-negotiable and must be incorporated into the system design from the outset.

Economic Considerations

Designing UPS systems for 24+ hour performance entails a substantial financial commitment. The cost of batteries increases disproportionately with longer runtimes, and additional infrastructure such as cooling systems, dedicated chargers, and safety mechanisms further inflate capital expenditures. Moreover, operational costs—including routine maintenance and periodic battery replacement—can be significant. While these investments may be justifiable for facilities with zero-tolerance for downtime, battery-only systems often yield a lower ROI compared to generator-based or hybrid alternatives unless uptime is of paramount importance.

Innovative Solutions

Surmounting these hurdles necessitates avant-garde methods, including sophisticated cell systems with lithium-ion for dense, enduring arrangements. Mixed mergers blend UPS with solar for unlimited duration in isolated cases. AI-based oversight employs foresighted data to forestall breakdowns and refine energy application.

Batteries Versus Fuel-Based Systems

While battery systems offer the advantages of silent operation, rapid response, and minimal emissions, they are not always the most practical solution for prolonged power supply. Alternatives such as diesel or natural gas generators, hydrogen fuel cells, and hybrid microgrid systems can often provide sustained power more economically and with greater scalability.

Each facility must weigh its environmental priorities, performance requirements, and budgetary constraints when selecting a long-duration power solution.

Hybrid and Alternative Approaches

To address the limitations of purely battery-based UPS systems, many organizations are turning to hybrid configurations. Common strategies include:

  • UPS + Generator Integration: Batteries handle the instantaneous switchover, while generators sustain longer
  • Battery + Fuel Cell Systems: Combine zero-emission operation with extended backup
  • Modular Energy Storage: Containerized battery units that are scalable and swappable.
  • Microgrid Configurations: Systems that integrate renewable energy sources, energy storage, and backup generation for autonomous power delivery.

These hybrid models allow for greater flexibility and resilience, particularly in environments where continuous operation is non-negotiable.

Custom Engineered Solutions by Power Solutions, LLC

Power Solutions LLC offers specialized engineering services for organizations requiring UPS runtimes of 24 hours or more. Our holistic approach to system design ensures that each solution is tailored to the client’s specific operational and regulatory environment. Key components of our design methodology include:

  • Battery Bank Sizing: Custom sizing based on load analysis and priority circuit identification.
  • Dedicated Battery Chargers: High-capacity chargers designed to operate independently of the inverter system, ensuring rapid battery recovery after discharge.
  • Properly Matched Inverters: Systems sized to balance both runtime and recharge demands, serving both critical and ancillary
  • Thermal and Structural Planning: Full consideration of cooling needs, spatial constraints, and building load-bearing
  • Regulatory Guidance: Support in navigating permitting processes and meeting compliance with local authorities having jurisdiction (AHJs).
  • Lifecycle Support: Monitoring, predictive maintenance, and system diagnostics to ensure long-term reliability and

By integrating all key system elements—battery banks, chargers, and inverters—into a unified design, Power Solutions LLC delivers UPS solutions that are both robust and compliant.

Conclusion

UPS systems capable of supporting 24+ hour runtimes are not only feasible but increasingly necessary in today’s risk-prone energy landscape. However, their successful deployment depends on meticulous engineering and strategic planning. Challenges related to battery scalability, inverter limitations, heat management, and code compliance must all be addressed to ensure safe, effective, and sustainable power continuity.

Through its experience and expertise, Power Solutions LLC provides comprehensive solutions that overcome these obstacles. Our integrated system designs ensure that critical facilities can maintain uninterrupted operations, even in the face of prolonged outages. For organizations where downtime is not an option, we offer the infrastructure, knowledge, and service necessary to make long-duration UPS performance a reality.

See the whitepaper version of this article.

For more information about designing for 24 hours of runtime